Intercambiador de Calor Tierra-Aire en Clima Mediterráneo. Periodo Térmico de Transición Frío-Calor

dc.contributor.authorMartínez-Bermúdez, Elizabeth
dc.contributor.authorFuentes Freixanet, Víctor Armando
dc.contributor.authorRincón-Martínez, Julio César
dc.contributor.coordinatorFuentes Freixanet, Víctor Armando
dc.contributor.coordinatorValerdi Madrigal, Héctor
dc.creatorMartínez-Bermúdez, Elizabeth;#0000-0002-7116-5668
dc.creatorFuentes Freixanet, Víctor Armando;#0000-0002-7426-2391
dc.creatorRincón-Martínez, Julio César;#0000-0002-1946-3609
dc.date.accessioned2026-07-03T19:14:46Z
dc.date.issued2022-04-22
dc.descriptionArtículo número 9 de Estudios de arquitectura bioclimática. Vol. I (enero-diciembre, 2022). Publicación anual de investigación en diseño. 14 páginas. eabi
dc.description.abstractLa humedad en espacios interiores genera impactos negativos en toda edificación y estos pueden producir efectos negativos en la salud de los usuarios. La OMS estima que esta afecta del 10-50% de los ambientes interiores en Europa, América del Norte, Australia, India y Japón. Mediante la gestión de los niveles de humedad interior y la condensación a través de un control adecuado de la temperatura y la ventilación, es posible controlar la humedad, garantizar una larga vida útil del edificio y una buena calidad del aire interior. El intercambiador de calor tierra-aire (ICTA) es el dispositivo propuesto, junto con la chimenea solar, para conformar un sistema pasivo que regule las condiciones higrotérmicas que permitan reducir los problemas de humedad en espacios interiores de la vivienda de interés social en clima mediterráneo. Con el análisis psicrométrico del ICTA durante el mes de marzo, se observa que en momentos fríos es cuando se presenta mayor diferencia entre las condiciones higrotérmicas del ambiente exterior con respecto a la salida del ICTA, de 8 ºC en temperatura y 30 % de humedad relativa. Respecto al desempeño higrotérmico, el ICTA presenta una estabilidad térmica en las tres profundidades, entre 17 ºC y 20 ºC, y una ligera diferencia con respecto a la salida del mismo; en los momentos fríos se observa una diferencia de casi 10 ºC entre el intercambiador en sus tres profundidades y la temperatura ambiente. Los días con mayores temperaturas, la temperatura en la salida del ICTA se encuentra dentro de la zona de confort (entre 17,7 ºC y 22,7 ºC para el periodo de transición de frío a cálido), mientras que en días fríos las temperaturas se encuentran cercanas al límite inferior. Por su parte, la humedad relativa se mantiene cercano al 60 % durante todo el mes.
dc.description.abstractHumidity in interior spaces generates negative impacts on all buildings and these can have negative effects on the user’s health. WHO estimates that it affects 10-50% of indoor environments in Europe, North America, Australia, India and Japan. By managing indoor humidity levels and condensation through proper temperature and ventilation control, it is posible to control humidity, ensure a long building life and good indoor air quality. The Earth-to-Air Heat Exchanger (EAHE) is the proposed device, together with the solar chimney, to form a passive system that regulates the hygrothermal conditions that allow reducing the humidity problems in interior spaces of social interest housing in a Mediterranean climate. With the psychrometric analysis of the EAHE during the month of March, it is observed that in cold moments is when there is a greater difference between the hygrothermal conditions of the outside environment with respect to that of the EAHE outlet, of 8 ºC in temperatura and 30% of RH. Regarding the hygrothermal performance, the EAHE presents a termal stability in the three depths, between 17 ºC and 20 ºC, and a slight difference with respect to output; in cold moments, a difference of almost 10 ºC is observed between the exchanger in three depths and the ambient temperature. On days with higher temperatures, the temperatura at the exit is in the comfort zone (between 17.7 ºC and 22.7 ºC for the transition period from cold to warm), while on cold days the temperatures are close to the lower limit. The relative humidity remains close to 60% throughout the month.
dc.formatpdf
dc.format.digitalOriginBorn digital
dc.identificator4||62||6201
dc.identifier.doihttps://doi.org/10.24275/issn.3061-8851.22.09
dc.identifier.urihttps://hdl.handle.net/11191/13789
dc.language.isospa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco.
dc.relation.ispartofhttps://hdl.handle.net/11191/9690
dc.rightsAtribución-NoComercial-SinDerivadas
dc.rights.accessopenAccess
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0
dc.sourceEstudios de arquitectura bioclimática. Vol. I (enero-diciembre, 2022). ISSN 3061-8851
dc.subjectIntercambiador de calor tierra-aire
dc.subjectSistema pasivo
dc.subjectVivienda de interés social
dc.subjectDesempeño higrotérmico.
dc.subject.classificationHUMANIDADES Y CIENCIAS DE LA CONDUCTA
dc.subject.classificationHUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS
dc.subject.classificationHUMANIDADES Y CIENCIAS DE LA CONDUCTA::CIENCIAS DE LAS ARTES Y LAS LETRAS::ARQUITECTURA
dc.titleIntercambiador de Calor Tierra-Aire en Clima Mediterráneo. Periodo Térmico de Transición Frío-Calor
dc.typeArtículo

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Intercambiador_de_Calor_Tierra-Aire_en_Clima_Mediterraneo_2022.pdf
Size:
3.36 MB
Format:
Adobe Portable Document Format
Description:
Intercambiador de Calor Tierra-Aire en Clima Mediterráneo...