Show simple item record

dc.contributor.authorLeyva Cruz, Edgar Oswaldo
dc.contributor.authorNegrón Silva, Guillermo Enrique
dc.contributor.authorValladares Rodríguez, María Rita
dc.contributor.authorFlores Valverde, Erasmo
dc.contributor.authorLópez Medina, Ricardo
dc.contributor.authorÁngeles Beltrán, Deyanira
dc.date.issued2020
dc.identifier.citationLeyva-Cruz, E.O., Negrón-Silva, G.E., Valladares-Rodríguez, M.R., Flores-Valverde, E., López-Medina, R. & Ángeles-Beltrán, D. (2020). Remoción de Cu (II) en efluentes acuosos utilizando hidrotalcita Mg/Fe. Revista Tendencias en Docencia e Investigación en Química, 6(6), 164-169. http://hdl.handle.net/11191/7703
dc.identifier.urihttp://hdl.handle.net/11191/7703
dc.description.abstractDebido al incremento de la contaminación en efluentes acuosos generado por algunos iones metálicos como son: Cu(II), Hg(II) y Cd(II), que en general provienen de actividades humanas e industriales, es necesario buscar metodologías para la remoción de estos contaminantes, ya que existe evidencia que muestra que la contaminación originada por el Cu(II), alcanza concentraciones de hasta 13.8 mg/l y es sabido que en la NOM-127-SSA1-1994 se establece que la concentración límite permisible en el agua potable no debe superar el 2 mg/l para cobre. En el presente trabajo se utilizó de manera exitosa un compuesto tipo hidrotalcita Mg/Fe sintetizado por la técnica de precipitación, en la remoción de iones de Cu(II) de soluciones acuosas partiendo de concentraciones de entre 15 y 30 ppm, logrando la remoción del 90% de dichos iones.
dc.description.abstractDue to the increase in pollution in aqueous effluents generated by some metal ions such as: Cu (II), Hg (II) and Cd (II), which generally come from human and industrial activities, it is necessary to seek methodologies for the removal of these pollutants, since there is evidence that shows that pollution caused by Cu (II), reaches concentrations of up to 13.8 mg / l and it is known that in the NOM-127-SSA1-1994 it is established that the permissible limit concentration in water drinking should not exceed 2 mg / l for copper. In the present work, a Mg / Fe hydrotalcite compound synthesized by the precipitation technique was successfully used in the removal of Cu (II) ions from aqueous solutions starting at concentrations between 15 and 30 ppm, achieving the removal of the 90% of these ions.
dc.formatpdf
dc.language.isospa
dc.publisherUniversidad Autónoma Metropolitana (México). Unidad Azcapotzalco. División de Ciencias Básicas e Ingeniería.
dc.relation.ispartofhttps://revistatediq.azc.uam.mx/Docs/Revista_TeDIQ_2020.pdf
dc.sourceRevista Tendencias en Docencia e Investigación en Química. Año 6, número 6 (enero-diciembre de 2020). ISSN: 2448-6663
dc.subjectRemoción, cobre, hidrotalcita. Removal, copper, hydrotalcite.
dc.subject.classificationINGENIERÍA Y TECNOLOGÍA::CIENCIAS TECNOLÓGICAS::INGENIERÍA Y TECNOLOGÍA DEL MEDIO AMBIENTE::ELIMINACIÓN DE RESIDUOS
dc.titleRemoción de Cu (II) en efluentes acuosos utilizando hidrotalcita Mg/Fe
dc.typeArtículo
dc.format.digitalOriginBorn digital


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record

Atribución-NoComercial-SinDerivadas
Except where otherwise noted, this item's license is described as Atribución-NoComercial-SinDerivadas